137 boilers & water heaters BACnet points lists from 29 manufacturers — A. O. Smith, AERCO, Bock Water Heaters, Bosch, Cleaver-Brooks, Contemporary Controls, Cosmogas, Fireye, Fulton, HTP, Hamilton Engineering, Heat-Timer, Hoval, Hydrotherm, Kemper, Laars, Lochinvar, Navien, PVI, Patterson-Kelley, Peerless, RBI, Raypak, Regin, Smith Cast Iron Boilers, Thermal Solutions, Viessmann, Watts, Weil-McLain. Each one has the full object table, the minimum points an integrator needs, enable and heartbeat notes, and CSV/EDE downloads. Click a column heading to sort.
137 of 137 shown
Unit type
| Type | Download | ||||
|---|---|---|---|---|---|
| A. O. Smith | A. O. Smith Custom Xi / Gold Xi electric water heaters (ETH-1000 / Mirius gateway)A. O. Smith Custom Xi and Gold Xi series commercial electric water heaters fitted with the ICC ETH-1000 or Mirius communication gateway. · 100329879_2000571701 Rev. C Also known as: Custom Xi, Gold Xi, Xi electric, ETH-1000, Mirius, 100316044, 100316045, ICC gateway | Water heater | 70 | 7 | CSVEDE |
| A. O. Smith | A. O. Smith Xi / MXi gas water heaters (ETH-1000 / Mirius gateway)A. O. Smith commercial gas water heaters with Xi 1.0 or MXi controls (such as Cyclone) fitted with the ICC ETH-1000 or Mirius communication gateway. · 100329879_2000571701 Rev. C Also known as: Cyclone Xi, Xi 1.0, MXi, ETH-1000, Mirius, 100316044, 100316045, ICC gateway, iCOMM | Water heater | 66 | 5 | CSVEDE |
| AERCO | AERCO AM Series Dependent boiler / water heater (ProtoNode FPC-N34/N35)AERCO AM Series boilers or water heaters set up as dependent units of a cascade, read through the AERCO ProtoNode FPC-N34 / FPC-N35. · OMM-0107_0B (GF-150) Also known as: AM Series, AM Dependent, AM Dep, AERCO AM, ProtoNode FPC-N34, FPC-N35 | BoilerWater heater | 49 | 8 | CSVEDE |
| AERCO | AERCO AM Series Managing boiler / water heater (ProtoNode FPC-N34/N35)AERCO AM Series boilers or water heaters set up as the managing (or stand-alone) unit of a cascade, read through the AERCO ProtoNode FPC-N34 / FPC-N35. · OMM-0107_0B (GF-150) Also known as: AM Series, AM Manager, AM Mngr, AERCO AM, ProtoNode FPC-N34, FPC-N35 | BoilerWater heater | 95 | 16 | CSVEDE |
| AERCO | AERCO Benchmark / Innovation Edge controller - BST Manager plant objectsAERCO Benchmark boilers and Innovation water heaters with an Edge [i] or Edge [ii] controller acting as BST Manager for up to 16 units, with optional SmartPlate / SmartPlate EV units. · OMM-0140J · unofficial source Also known as: BST Manager, Boiler Sequencing Technology, Edge [i], Edge [ii], Benchmark Edge, BMK Edge, Innovation Edge, OMM-0140, SmartPlate via Edge | Boiler | 100 | 37 | CSVEDE |
| AERCO | AERCO Benchmark E / Edge XAERCO Benchmark E (BMK E) condensing boilers with the Edge X controller, including BST cascade plants; the table also lists the legacy Benchmark (BMK) Edge equivalents. · OMM-0173E Also known as: BMK E, BMKE, Benchmark, Edge X, Edge controller, OMM-0173 | Boiler | 390 | 38 | CSVEDE |
| AERCO | AERCO C-More boilers / water heaters with BST or WHM (ProtoNode RER SSD)AERCO C-More boilers running on-board BST sequencing and C-More water heaters (KC, Innovation) running WHM, up to 8 units, through the ProtoNode RER SSD profile. · OMM-0080_0H Also known as: C-More, BST, Boiler Sequencing Technology, WHM, Water Heater Management, SSD, Slave/Slave Device, Innovation, KC, Benchmark, ProtoNode RER, 64084, GF-129, OMM-0080 | BoilerWater heater | 46 | 5 | CSVEDE |
| AERCO | AERCO C-More boilers with ACS / BMS II (ProtoNode RER)AERCO boilers with the C-More controller plus an ACS or BMS II plant sequencer, read through the AERCO ProtoNode RER. · OMM-0080_0H Also known as: C-More, C-More controller, ACS, BMS II, BMS, ProtoNode RER, ProtoNode-RER, 64084, FPC-N34, GF-129, OMM-0080 | Boiler | 162 | 13 | CSVEDE |
| AERCO | AERCO Combined plant: 12 C-More, 4 Modulex, 6 ECS/SmartPlate, 2 BMS II (ProtoNode points list)A combined AERCO plant of 12 C-More boilers, 4 Modulex boilers, 6 ECS/SmartPlate water heater valves and two BMS II boiler managers on one gateway. Also known as: AERCO ProtoNode, C-More, Modulex, ECS, SmartPlate, BMS II, AERCO-ProtoNode-Control-Points | BoilerWater heater | 232 | 28 | CSVEDE |
| AERCO | AERCO ECS and SmartPlate water heaters (ProtoNode RER)AERCO SmartPlate and ECS (Electric Valve) water heaters, up to four, read through the AERCO ProtoNode RER. · OMM-0080_0H Also known as: ECS, Electronic Control System, SmartPlate, SmartPlate water heater, E Valve, ProtoNode RER, 64084, GF-129, OMM-0080 | Water heater | 28 | 4 | CSVEDE |
| AERCO | AERCO Edge [ii] water heater controller (standalone / WHM)AERCO Innovation 1600-2000 water heaters with the Edge [ii] controller, run standalone or as a WHM (Water Heater Management) manager or client. · OMM-0162C Also known as: Edge [ii], Edge ii, Edge 2, WHM, Water Heater Management, Centurion, OMM-0176, Innovation 1600-2000 | Water heater | 206 | 73 | CSVEDE |
| AERCO | AERCO Modulex boilers with BCM and ACS / BMS II (ProtoNode RER)AERCO Modulex boilers with a BCM, up to four, plus an ACS or BMS II sequencer, read through the AERCO ProtoNode RER. · OMM-0080_0H Also known as: Modulex, MLX, Modulex E8, BCM, ACS, BMS II, ProtoNode RER, 64084, GF-129, OMM-0080 | Boiler | 54 | 9 | CSVEDE |
| Bock Water Heaters | Bock Water Heaters Carlin EZTemp 51110A7 electric water heater controlBock electric water heaters fitted with the Carlin EZTemp 51110A7 control. · unofficial source Also known as: 51110A7, Carlin EZTemp, EZTemp, Bock electric water heater BACnet | Water heater | 21 | 2 | CSVEDE |
| Bosch | Bosch Buderus Cascade SSB 255 / 399 / 512 (ProtoAir FPA-W44, C_Platform)Bosch/Buderus SSB 255, 399 and 512 condensing boilers in a cascade (C_Platform), read through the ProtoAir FPA-W44 gateway. · Document Revision 5.D Also known as: SSB 255, SSB 399, SSB 512, Buderus SSB, C_Platform, ProtoAir FPA-W44, Bosch cascade | Boiler | 154 | 14 | CSVEDE |
| Bosch | Bosch Buderus SSB800 / SSB1000 / SSB1000TL boiler (ProtoNode FPC-N38)Bosch Buderus SSB800, SSB1000 and SSB1000TL condensing boilers (D_Platform control) connected through a ProtoNode FPC-N38 gateway. · Document Revision 4.B (Web Configurator Template Revision 70) Also known as: SSB800, SSB1000, SSB1000TL, Buderus SSB, Bosch SSB, ProtoNode FPC-N38, D_Platform | BoilerCondensing | 147 | 10 | CSVEDE |
| Bosch | Bosch Heatronic 4000 boiler plant controlBosch Heatronic 4000 control that runs up to four boilers for heating and DHW loads (product now discontinued). · BTC 461501103 B (6720810375) Also known as: Heatronic 4000, Bosch 4000, Heatronic, J1229A | Boiler | 72 | 13 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks ADAC 1000 deaerator / surge tank control (ProtoNode, EtherNet/IP)Cleaver-Brooks deaerator and surge tank packages with the ADAC 1000 PLC control, read through a ProtoNode RER gateway over EtherNet/IP. · 750-426 · unofficial source Also known as: ADAC 1000, ADAC_1000, ProtoNode RER, 750-426 | Boiler | 338 | 62 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks ADAC deaerator / surge tank control (ProtoNode)Cleaver-Brooks deaerator and surge tank packages with the ADAC control, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: ADAC, CB deaerator control, ProtoNode RER, 750-426 | Boiler | 265 | 0 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks CB120 flame safeguard (ProtoNode)Cleaver-Brooks boilers with the CB120 flame safeguard, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: CB120, CB 120, ProtoNode RER, 750-426 | Boiler | 94 | 0 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks CB780 flame safeguard with expanded annunciator (ProtoNode)Cleaver-Brooks boilers with the CB780 burner management control and expanded annunciator, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: CB780, CB 780, CB780E, ProtoNode RER, 750-426 | Boiler | 93 | 1 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks Falcon Hydronic boiler control (ProtoNode)Cleaver-Brooks hot water boilers with the Falcon hydronic burner control, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: Falcon Hydronic, ClearFire Falcon, CB Falcon, ProtoNode RER, 750-426 | Boiler | 90 | 7 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks Falcon Steam boiler control (ProtoNode)Cleaver-Brooks steam boilers with the Falcon steam burner control, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: Falcon Steam, CB Falcon steam, ProtoNode RER, 750-426 | Boiler | 62 | 5 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks FARC with CB780 / CB783 burner control (ProtoNode)Cleaver-Brooks boilers with a CB780/CB783 burner control and FARC fuel-air ratio control, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: FARC, CB 780/783, CB783, ProtoNode RER, 750-426 | Boiler | 178 | 0 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks Hawk 1000 boiler control (ProtoNode)Cleaver-Brooks boilers with the Hawk 1000 PLC boiler control, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: Hawk 1000, CB Hawk 1000, ProtoNode RER, 750-426 | Boiler | 268 | 42 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks Hawk 2000 boiler control (ProtoNode)Cleaver-Brooks boilers with the Hawk 2000 control, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: Hawk 2000, CB Hawk 2000, ProtoNode RER, 750-426 | Boiler | 75 | 0 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks Hawk 4000 boiler control (ProtoNode)Cleaver-Brooks boilers with the Hawk 4000 PLC boiler control, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: Hawk 4000, CB Hawk 4000, ProtoNode RER, 750-426 | Boiler | 283 | 42 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks Hawk 4000 V2 boiler control (ProtoNode)Cleaver-Brooks boilers with the HAWK 4000 V2 PLC boiler control, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: HAWK 4000 V2, CB HAWK 4000 V2, HAWK_4000_V2, ProtoNode RER, 750-426 | Boiler | 378 | 42 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks Hawk 4500 boiler control (ProtoNode, EtherNet/IP)Cleaver-Brooks boilers with the Hawk 4500 PLC boiler control, read through a ProtoNode RER gateway over EtherNet/IP. · 750-426 · unofficial source Also known as: Hawk 4500, CB Hawk 4500, ProtoNode RER, 750-426 | Boiler | 420 | 42 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks Hawk 5000 boiler control (ProtoNode)Cleaver-Brooks steam boilers with the Hawk 5000 control, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: Hawk 5000, CB Hawk 5000, ProtoNode RER, 750-426 | Boiler | 266 | 0 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks Hawk ICS boiler control (ProtoNode)Cleaver-Brooks boilers with the Hawk ICS control, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: Hawk ICS, CB ICS, ProtoNode RER, 750-426 | Boiler | 140 | 0 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks Hawk Master Panel lead/lag (ProtoNode)Cleaver-Brooks Hawk Master Panels sequencing up to eight Hawk boilers (A-H), read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: Hawk Master Panel, Hawk Master, CB Master Panel, ProtoNode RER, 750-426 | Boiler | 196 | 52 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks HSC Boiler Interface Module (ProtoNode)Cleaver-Brooks HSC boiler interface modules (one boiler each), read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: Boiler Interface Module, HSC Boiler Interface, BIM, ProtoNode RER, 750-426 | Boiler | 40 | 9 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks HSC Hydronic System Controller (ProtoNode)Cleaver-Brooks HSC panels sequencing up to 10 condensing and 10 non-condensing boilers, read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: HSC, Hydronic System Controller, CB HSC, ProtoNode RER, 750-426 | Boiler | 318 | 4 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks HSC Pump Interface Module (ProtoNode)Cleaver-Brooks HSC pump interface modules (up to four system pumps), read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: Pump Interface Module, HSC Pump Interface, ProtoNode RER, 750-426 | Boiler | 47 | 3 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks LCS Level Control System (ProtoNode)Cleaver-Brooks LCS water level controllers (one or two tanks), read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: LCS, Level Control System, ProtoNode RER, 750-426 | Boiler | 59 | 0 | CSVEDE |
| Cleaver-Brooks | Cleaver-Brooks PCS Pump Control System (ProtoNode)Cleaver-Brooks PCS pump controllers (up to four pumps on header pressure or tank level), read through a ProtoNode RER gateway. · 750-426 · unofficial source Also known as: PCS, Pump Control System, ProtoNode RER, 750-426 | Boiler | 57 | 0 | CSVEDE |
| Contemporary Controls | Contemporary Controls Advanced Thermal Hydronics (Hydrotherm) KN-2 / KN-4 via BASgatewayLXHydrotherm / Advanced Thermal Hydronics KN-2 and KN-4 modular boilers with the KN boiler-room controller on Modbus, read by a BASgatewayLX. · Hydrotherm_KN2_KN4_aRY_Boiler_a_LX.csv Also known as: Hydrotherm KN, KN-2, KN-4, Advanced Thermal Hydronics, Mastek KN | Boiler | 674 | 18 | CSVEDE |
| Contemporary Controls | Contemporary Controls AERCO BMS / BMS II Boiler Management System via BASgatewayLXAERCO BMS and BMS II boiler management systems on Modbus, read by a BASgatewayLX. · Aerco_Boiler_Mgmt_System_BMS_BMSII_LX.csv Also known as: AERCO BMS, AERCO BMS II, Boiler Management System, BMSII | Boiler | 188 | 0 | CSVEDE |
| Contemporary Controls | Contemporary Controls AERCO C-More Boiler Controller via BASgatewayLXAERCO boilers and water heaters with the C-More control on Modbus, read by a BASgatewayLX. · Aerco_C_More_Boiler_Controller_LX.csv Also known as: C-More, AERCO Benchmark C-More, KC1000 C-More | Boiler | 82 | 0 | CSVEDE |
| Contemporary Controls | Contemporary Controls Cleaver-Brooks Falcon (Honeywell SOLA-based) boiler control via BASgatewayLXCleaver-Brooks Falcon hydronic boiler controls on Modbus, read by a BASgatewayLX. · CleaverBrooks_Falcon_b_LX.csv Also known as: Falcon, CB Falcon, Cleaver Brooks Falcon Modbus, 750-308 | Boiler | 816 | 580 | CSVEDE |
| Contemporary Controls | Contemporary Controls ebm-papst ArgusVision Dependent Boiler via BASgatewayLXBoilers with an ebm-papst ArgusVision control running as a dependent (cascade member), read over Modbus by a BASgatewayLX. · DEPENDENT_BOILER_a_LX.csv Also known as: ArgusVision, ebmpapst dependent boiler, Argus boiler control | Boiler | 47 | 10 | CSVEDE |
| Contemporary Controls | Contemporary Controls ebm-papst ArgusVision Trio Managing Boiler via BASgatewayLXBoilers with an ebm-papst ArgusVision control acting as the managing (lead) boiler of a cascade, read over Modbus by a BASgatewayLX. · TRIO_MANAGING_BOILER_a_LX.csv Also known as: ArgusVision Trio, ebmpapst managing boiler, Argus cascade master | Boiler | 78 | 30 | CSVEDE |
| Contemporary Controls | Contemporary Controls Fireye PPC4000 parallel positioning control via BASgatewayLXFireye PPC4000 fuel/air parallel positioning controls on boilers, read over Modbus by a BASgatewayLX. · Fireye_PPC4000_a_LX.csv Also known as: PPC4000, PPC 4000, Fireye PPC-4000 | Boiler | 153 | 0 | CSVEDE |
| Contemporary Controls | Contemporary Controls Harsco Patterson-Kelley NURO via BASgatewayLXPatterson-Kelley NURO condensing boilers (Harsco) on Modbus, read by a BASgatewayLX. · Harsco_Patterson_NURO_a_LX.csv Also known as: NURO, Patterson-Kelley NURO, Harsco Air-Xchange NURO, P-K NURO | Boiler | 50 | 0 | CSVEDE |
| Contemporary Controls | Contemporary Controls Honeywell 7800 SERIES burner control (S7800A1142 display) via BASgatewayLXHoneywell 7800 SERIES relay modules (RM/EC7800) with the S7800A1142 keyboard display module providing Modbus, read by a BASgatewayLX. · Honeywell_7800SERIES_Burner_a_LX.csv Also known as: S7800A1142, 7800 SERIES, RM7800, EC7800, Honeywell burner control Modbus | Boiler | 283 | 0 | CSVEDE |
| Contemporary Controls | Contemporary Controls Lochinvar Armor, Knight, FTXL and Wall Mount via BASgatewayLXLochinvar Knight (KB/KBX), Knight Wall Mount (WB), Armor (AW) and FTXL boilers and water heaters with SMART SYSTEM Modbus, read by a BASgatewayLX. · Lochinvar_WB__AW__KB__KBX_LX.csv Also known as: Lochinvar Knight, Lochinvar Armor, FTXL, Knight Wall Mount, WB, AW, KB, KBX, SMART SYSTEM Modbus | BoilerWater heater | 48 | 19 | CSVEDE |
| Contemporary Controls | Contemporary Controls Lochinvar Crest boiler via BASgatewayLXLochinvar Crest commercial condensing boilers with SMART SYSTEM Modbus, read by a BASgatewayLX. · Lochinvar_Crest_Boiler_LX.csv Also known as: Crest, Lochinvar Crest Modbus, FBN Crest | Boiler | 59 | 16 | CSVEDE |
| Contemporary Controls | Contemporary Controls PVI Industries TempTrac water heater control via BASgatewayLXPVI Industries commercial water heaters with the TempTrac control on Modbus, read by a BASgatewayLX. · PVI_Ind_TempTrac_Water_Heater_a_LX.csv Also known as: TempTrac, PVI TempTrac, PVI water heater Modbus | Water heater | 123 | 0 | CSVEDE |
| Contemporary Controls | Contemporary Controls PVI Industries XR10CX controller via BASgatewayLXPVI Industries water heaters using the XR10CX digital controller on Modbus, read by a BASgatewayLX. · PVI_Industries_XR10CX_a_LX.csv Also known as: XR10CX, Dixell XR10CX, PVI XR10CX Modbus | Water heater | 22 | 9 | CSVEDE |
| Contemporary Controls | Contemporary Controls Siemens LMV3 burner management via BASgatewayLXSiemens LMV3 (LMV26/36/37) burner management systems with Modbus, read by a BASgatewayLX. · Siemens_Combustion_Control_LMV3_a_LX.csv Also known as: LMV3, LMV36, LMV37, LMV26, Siemens LMV Modbus | Boiler | 246 | 14 | CSVEDE |
| Contemporary Controls | Contemporary Controls Siemens LMV5 burner management via BASgatewayLXSiemens LMV5 (LMV51/52) burner management systems with Modbus through the AZL5 display, read by a BASgatewayLX. · Siemens_Combustion_Control_LMV5_a_LX.csv Also known as: LMV5, LMV51, LMV52, Siemens LMV5 Modbus, AZL5 | Boiler | 142 | 31 | CSVEDE |
| Contemporary Controls | Contemporary Controls Siemens SCC TS-1100 touchscreen (LMV3/LMV5/RWF, Modbus RTU) via BASgatewayLXBoilers with an SCC/Siemens TS-1100 touchscreen fronting LMV3 or LMV5 burner management and RWF40/55 controllers, read over Modbus RTU by a BASgatewayLX. · TS1100TouchS_RTU_LMV3_LMV5_RWF_a_LX.csv Also known as: TS-1100, TS1100, SCC TS-1100 touchscreen, LMV RWF touchscreen | Boiler | 130 | 6 | CSVEDE |
| Contemporary Controls | Contemporary Controls U.S. Boiler Company Sage2 combustion controller via BASgatewayLXU.S. Boiler (Burnham) boilers with the Sage2 combustion controller on Modbus, read by a BASgatewayLX. · US_Boiler_SAGE2_COMB_Controller_a_LX.csv Also known as: Sage2, SAGE2.1, US Boiler Sage, Burnham Sage2 | Boiler | 308 | 5 | CSVEDE |
| Cosmogas | Cosmogas Argus boiler control via ProtoNode RER / LERCosmogas boilers with the Argus managing/standalone control, including up to four dependent burners, through a ProtoNode RER (BACnet) gateway. · Instruction 62403594 R08 Also known as: Cosmogas Argus BACnet, Argus managing boiler, Argus dependent boiler, RBI Infinite Energy 2 BACnet, ProtoNode RER FPC-N34-1626, ProtoNode LER FPC-N35-1625 | Boiler | 41 | 11 | CSVEDE |
| Fireye | Fireye Nexus NX6100 / PPC6000 burner control (NXTSD104 / NX6330 touchscreen, BACnet IP)Fireye Nexus NX6100 and PPC6000 integrated burner/boiler controls connected through an NXTSD104 or NX6330 touchscreen (firmware 2.200 or later), including twin-burner and 62xx expansion units. · MOD-6001 Also known as: NX6100, PPC6000, Nexus NX6100, Fireye Nexus, NXTSD104, NX6330, MOD-6001, Fireye PPC6000, Fireye 6000 series | Boiler | 57 | 20 | CSVEDE |
| Fulton | Fulton Boiler with Siemens LMV3 (N54 ProtoNode)Fulton boilers with a Siemens LMV3 burner management control, read through Fulton's N54 ProtoNode gateway. Also known as: LMV3, LMV 3, Siemens LMV3, N54 ProtoNode, Fulton ProtoNode | Boiler | 28 | 3 | CSVEDE |
| Fulton | Fulton Boiler with Siemens LMV3 and Yokogawa UT32A (N54 ProtoNode)Fulton hydronic boilers with a Siemens LMV3 burner control and a Yokogawa UT32A temperature controller, read through the N54 ProtoNode. Also known as: LMV3, Siemens LMV3, Yokogawa UT32A, UT32A, N54 ProtoNode | Boiler | 30 | 4 | CSVEDE |
| Fulton | Fulton Hydronic ModSync SE v6.6.1.X (N54 ProtoNode)Fulton ModSync SE hydronic boiler sequencer (software 6.6.1.X) managing up to 8 boilers, read through the N54 ProtoNode. Also known as: ModSync, ModSync SE, Fulton ModSync, ModSync sequencer, N54 ProtoNode | Boiler | 164 | 11 | CSVEDE |
| Fulton | Fulton Hydronic SOLA Boiler (N54 ProtoNode)Fulton hydronic boilers with the SOLA burner control, one block of objects per boiler on the N54 ProtoNode. Also known as: SOLA, Fulton SOLA, Honeywell SOLA, N54 ProtoNode | Boiler | 41 | 8 | CSVEDE |
| Fulton | Fulton Hydronic SOLA Master (lead/lag) (N54 ProtoNode)The SOLA lead/lag master of a group of Fulton hydronic boilers (up to 8 slaves), read through the N54 ProtoNode. Also known as: SOLA Master, Fulton SOLA lead lag, N54 ProtoNode | Boiler | 65 | 8 | CSVEDE |
| Fulton | Fulton PURE Control - Endura EDR 750-2000 Provider (N54 ProtoNode)The Provider (lead) boiler of a Fulton Endura (EDR) 750-2000 hydronic lead/lag group with the PURE control, read through the N54 ProtoNode. Also known as: Endura, EDR 750, EDR 2000, EDR 2MM, Fulton PURE Provider, N54 ProtoNode | Boiler | 81 | 7 | CSVEDE |
| Fulton | Fulton PURE Control - Endura EDR 750-2000 Single (N54 ProtoNode)Fulton Endura (EDR) 750-2000 hydronic boilers with the PURE control, one boiler per address block on the N54 ProtoNode. Also known as: Endura, EDR 750, EDR 2000, EDR 2MM, Fulton PURE, N54 ProtoNode | Boiler | 50 | 7 | CSVEDE |
| Fulton | Fulton PURE Control - Endura XE EXE 399-750 Provider (N54 ProtoNode)The Provider (lead) boiler of a Fulton Endura XE (EXE) 399-750 hydronic lead/lag group with the PURE control, read through the N54 ProtoNode. Also known as: Endura XE, EXE 399, EXE 750, Fulton PURE Provider, N54 ProtoNode | Boiler | 80 | 7 | CSVEDE |
| Fulton | Fulton PURE Control - Endura XE EXE 399-750 Single (N54 ProtoNode)Fulton Endura XE (EXE) 399-750 hydronic boilers with the PURE control, one boiler per address block on the N54 ProtoNode. Also known as: Endura XE, EXE 399, EXE 750, Fulton PURE, N54 ProtoNode | Boiler | 49 | 7 | CSVEDE |
| Fulton | Fulton PURE Control - Endura ZE Provider (N54 ProtoNode)The Provider (lead) boiler of a Fulton Endura (EDR) ZE lead/lag group with the PURE control, read through the N54 ProtoNode. Also known as: Endura ZE, EDR ZE, Fulton PURE Provider, N54 ProtoNode | Boiler | 103 | 8 | CSVEDE |
| Fulton | Fulton PURE Control - Endura ZE Single (N54 ProtoNode)Fulton Endura (EDR) ZE boilers with the PURE control, one boiler per address block on the N54 ProtoNode. Also known as: Endura ZE, EDR ZE, Fulton PURE, N54 ProtoNode | Boiler | 72 | 8 | CSVEDE |
| Fulton | Fulton PURE Control - Endura+ EDR+ 2500-6000 (N54 ProtoNode)Fulton hydronic boilers run by the PURE control (the file name points to Endura+ EDR+ 2500-6000 MBH sizes), read through the N54 ProtoNode. Also known as: PURE, Fulton PURE, Endura+, EDR+, Endura Plus, Hydronic PURE, N54 ProtoNode | Boiler | 58 | 7 | CSVEDE |
| Fulton | Fulton PURE Control - Endura+ EDR+ 2500-6000 Provider (N54 ProtoNode)The Provider (lead) boiler of a Fulton Endura+ (EDR+) 2500-6000 hydronic lead/lag group with the PURE control, read through the N54 ProtoNode. Also known as: Endura+, EDR+, Endura Plus, EDR+ 2500, EDR+ 6000, Fulton PURE Provider, N54 ProtoNode | Boiler | 99 | 7 | CSVEDE |
| Fulton | Fulton PURE Control - VSRT Steam Boiler Provider (N54 ProtoNode)The Provider (lead) boiler of a Fulton VSRT steam boiler lead/lag group with the PURE control, read through the N54 ProtoNode. Also known as: VSRT, Fulton VSRT, Steam PURE Provider, N54 ProtoNode | Boiler | 78 | 5 | CSVEDE |
| Fulton | Fulton PURE Control - VSRT Steam Boiler Single (N54 ProtoNode)Fulton VSRT steam boilers with the PURE control, one boiler per address block on the N54 ProtoNode. Also known as: VSRT, Fulton VSRT, Steam PURE, Fulton PURE, N54 ProtoNode | Boiler | 47 | 5 | CSVEDE |
| Fulton | Fulton Siemens LMV36 with BACnet InterfaceFulton boilers with a Siemens LMV36 burner control on a BACnet interface. Also known as: LMV36, Siemens LMV36, LMV3, Fulton LMV36 | Boiler | 21 | 3 | CSVEDE |
| Fulton | Fulton Siemens LMV5 Steam Boiler with BACnet InterfaceFulton steam boilers whose Siemens LMV5 burner management is given a BACnet interface (standard configurations). Also known as: LMV5, Siemens LMV5, LMV52, Fulton LMV5 | Boiler | 26 | 7 | CSVEDE |
| Fulton | Fulton Steam ModSync SE v6.6.1.0 (ProtoNode)Fulton ModSync SE steam boiler sequencer (version 6.6.1.0) managing up to 8 steam boilers, read through a Sierra Monitor ProtoNode. Also known as: ModSync SE, ModSync, Fulton ModSync steam, ProtoNode | Boiler | 104 | 4 | CSVEDE |
| Hamilton Engineering | Hamilton Engineering BDB-CDB (ProtoNode FPC-N54)Hamilton Engineering equipment with the BDB-CDB control, which reports cascade values and up to eight BCB blocks (BCB1-BCB8), connected through a ProtoNode FPC-N54. · Document Revision 2.A (Web Configurator Template Revision 3) Also known as: BDB-CDB, BDB, CDB, ProtoNode FPC-N54, FPC-N54-1776, Hamilton ProtoNode | Boiler | 36 | 18 | CSVEDE |
| Heat-Timer | Heat-Timer HWR Platinum (BACnet)Heat-Timer HWR Platinum hot water reset control for a single burner or a motorized mixing valve, with the BACnet IP/MS/TP communication board. · HT# 059082-00C Also known as: HWR, HWR Platinum, Heat-Timer HWR, Platinum BACnet | Boiler | 32 | 25 | CSVEDE |
| Heat-Timer | Heat-Timer HWRQ Platinum (BACnet)Heat-Timer HWRQ Platinum hot water reset and sequencing control for multiple on/off or staged boilers, with the BACnet IP/MS/TP board. · HT# 059082-00C Also known as: HWRQ, HWRQ Platinum, Heat-Timer HWRQ, Platinum BACnet | Boiler | 50 | 41 | CSVEDE |
| Heat-Timer | Heat-Timer MPC Platinum (BACnet)Heat-Timer MPC Platinum heating control for a burner/valve or district steam plant, with the BACnet IP/MS/TP board. · HT# 059082-00C Also known as: MPC, MPC Platinum, Heat-Timer MPC, Platinum BACnet | Boiler | 32 | 27 | CSVEDE |
| Heat-Timer | Heat-Timer MPCQ Platinum (BACnet)Heat-Timer MPCQ Platinum steam heating and boiler sequencing control (pressure based), with the BACnet IP/MS/TP board. · HT# 059082-00C Also known as: MPCQ, MPCQ Platinum, Heat-Timer MPCQ, Platinum BACnet | Boiler | 49 | 40 | CSVEDE |
| Heat-Timer | Heat-Timer Multi-MOD Platinum (BACnet)Heat-Timer Multi-MOD Platinum control for up to 20 modulating boilers or stages (hot water, steam or reset), with the BACnet IP/MS/TP board. · HT# 059082-00C Also known as: Multi-MOD, MultiMOD, Multi-MOD Platinum, Heat-Timer Multi-MOD, Platinum BACnet | Boiler | 43 | 29 | CSVEDE |
| Heat-Timer | Heat-Timer SRC Platinum (BACnet)Heat-Timer SRC Platinum steam heating control for a burner/valve or district steam valve, with the BACnet IP/MS/TP board. · HT# 059082-00C Also known as: SRC, SRC Platinum, Heat-Timer SRC, Platinum BACnet | Boiler | 41 | 35 | CSVEDE |
| Hoval | Hoval TopTronic E BACnet datapoints, use case 7 (heat generator, 3 circuits, hot water, buffer, ventilation)Hoval TopTronic E systems with a heat generator, three heating circuits, hot water, a heating/cooling buffer and ventilation, read through an Intesis BACnet server polling Hoval Connect over Modbus TCP. Also known as: Hoval use case 7, Hoval Anwendungsfall 7, TopTronic E use case 7, TTE BACnet use case 7, Hoval Connect BACnet | Boiler | 58 | 0 | CSVEDE |
| Hoval | Hoval TopTronic E heat generator via Hoval Modbus/BACnet gateway (standard datapoints)Hoval heat generators with TopTronic E controls (heat generator, up to 3 heating circuits and hot water) connected to BACnet through the Hoval Modbus-to-BACnet gateway (Intesis). Also known as: TopTronic E, TTE, Hoval TTE BACnet, Hoval TopTronic E BACnet, Hoval Modbus BACnet gateway, TTE ModBus BACnet Datapoints | Boiler | 54 | 18 | CSVEDE |
| HTP | HTP MODBUS/BACnet Adapter 7350P-636 (BIC-926/928 boilers and water heaters)HTP boilers and water heaters with BIC-926 or BIC-928 controls (BIC-928: EnduroTI and Elite Premier boilers; BIC-926: Modcon, Modcon VWH, Pioneer and Versa Flame built from July 2011, and Elite, Elite VWH and Phoenix water heaters built from August 2011) fitted with the 7350P-636 MODBUS/BACnet adapter. · LP-548 Rev. 000 Rel. 006 Also known as: 7350P-636, 64980290, HTP MODBUS/BACnet adapter, LP-548, BIC-928, BIC-926, EnduroTI, Elite Premier, Modcon, Modcon VWH, Pioneer, Versa Flame, Elite VWH, Phoenix | BoilerWater heater | 111 | 15 | CSVEDE |
| Hydrotherm | Hydrotherm KN / KN+ Series boilers with HeatNet V3 controlHydrotherm (Mestek) KN and KN+ Series condensing boilers with a HeatNet V3 control board (firmware 4.20+), including HeatNet cascades of up to 16 boilers. · v2.00 Also known as: HeatNet V3, HeatNet, KN Series, KN+, KN-Series, ATH, Mestek, KN BACnet Objects | Boiler | 101 | 20 | CSVEDE |
| Hydrotherm | Hydrotherm KN Series (KNSX) boilers - HeatNet BACnet BridgeHydrotherm (Mestek) KN Series boilers covered by the KNSX object list, with a HeatNet control and a HeatNet BACnet IP or BACnet MS/TP bridge. · v2.52 Also known as: KNSX, KN Series, HeatNet, HeatNet bridge, Mestek | Boiler | 86 | 18 | CSVEDE |
| Hydrotherm | Hydrotherm KN2 / KN4 / rAy boilers - HeatNet BACnet BridgeHydrotherm (Mestek) KN2 and KN4 boilers and rAy boilers with a HeatNet control and a HeatNet BACnet IP or BACnet MS/TP bridge (bridge configuration 2.40+). · v2.50 Also known as: KN2, KN-2, KN4, KN-4, rAy, HeatNet, HeatNet bridge, KNSLM, Mestek | Boiler | 75 | 18 | CSVEDE |
| Kemper | Kemper KTS BACnet Gateway Fig. 916 02 022 (KTS hot water stations)Kemper KTS potable hot water stations (single unit or cascades of up to 8 stations) connected through the KTS BACnet Gateway Fig. 916 02 022. · dok_tin_me130144 Also known as: Fig. 916 02 022, 916 02 022, KTS Gateway, Kemper KTS, KTS BACnet | Water heater | 46 | 13 | CSVEDE |
| Laars | Laars HTD control - ProtoNodeLaars boilers with the HTD control, read through a ProtoNode FPC-N34 gateway (the document does not name the models). · 4404 Also known as: HTD, Laars HTD, ProtoNode FPC-N34, ProtoNode FPC-N35, FPC-N34-0701, Laars ProtoNode | Boiler | 180 | 47 | CSVEDE |
| Laars | Laars MagnaTherm - ProtoNodeLaars MagnaTherm units, read through a ProtoNode FPC-N34 gateway. · 4404 Also known as: MagnaTherm, Laars MagnaTherm, ProtoNode FPC-N34, ProtoNode FPC-N35, FPC-N34-0701, Laars ProtoNode | Boiler | 121 | 30 | CSVEDE |
| Laars | Laars Multiburner control - ProtoNodeLaars boilers with the Multiburner control, read through a ProtoNode FPC-N34 gateway (the document does not name the models). · 4404 Also known as: Multiburner, Laars Multiburner, Multi-burner, ProtoNode FPC-N34, ProtoNode FPC-N35, FPC-N34-0701, Laars ProtoNode | Boiler | 149 | 48 | CSVEDE |
| Laars | Laars OmniTherm - ProtoNodeLaars OmniTherm units, read through a ProtoNode FPC-N34 gateway. · 4404 Also known as: OmniTherm, Laars OmniTherm, ProtoNode FPC-N34, ProtoNode FPC-N35, FPC-N34-0701, Laars ProtoNode | Boiler | 121 | 28 | CSVEDE |
| Laars | Laars Sola control - ProtoNodeLaars boilers with the Sola control, read through a ProtoNode FPC-N34 gateway (the document does not name the models). · 4404 Also known as: Sola, Laars Sola, ProtoNode FPC-N34, ProtoNode FPC-N35, FPC-N34-0701, Laars ProtoNode | Boiler | 88 | 24 | CSVEDE |
| Lochinvar | Lochinvar Armor 1250-4000 water heater (SMART SYSTEM)Lochinvar Armor volume water heaters, models 1250-4000, Series 100 and 101, with the SMART SYSTEM control and the Modbus/BACnet communication board. · 100305786_2000558371 Rev C Also known as: Armor, Armor 1250, Armor 4000, AWH, Armor Series 100, Armor Series 101, SMART SYSTEM, MTR-01, 100305786 | Water heaterCondensing | 44 | 7 | CSVEDE |
| Lochinvar | Lochinvar Copper-fin II / IIE (CFX, CHX, CPX)Lochinvar Copper-fin II/IIE boilers and water heaters (models 402-2072) and pool heaters (502-2072) with the SMART SYSTEM control. · C(F,H,P)X-MODB 100160882_2000001229 Also known as: Copper-fin, Copper-Fin II, Copper-fin IIE, CFX, CHX, CPX, C(F,H,P)X-MODB, CB 402-2072, CW 402-2072 | BoilerWater heater | 59 | 13 | CSVEDE |
| Lochinvar | Lochinvar CrestCrest FB/OF 751-6001 and FCB 1000-6000 condensing boilers (the manual uses the same map for Hellcat). · 100161012_2000020084 Also known as: Crest FB, Crest OF, Crest FCB, Hellcat | BoilerCondensing | 77 | 10 | CSVEDE |
| Lochinvar | Lochinvar Knight / Armor (SMART TOUCH)Knight, Knight XL, Armor, Wall Mount, Wall Hung, AQUAS, FTXL and Shield boilers and water heaters with the SMART TOUCH control. · MODB-I-O_100161545_2000014822 Also known as: Knight XL, Outdoor Knight, Armor, Wall Mount, Wall Hung, AQUAS, FTXL, Shield, MODB-I-O | BoilerWater heaterCondensing | 44 | 11 | CSVEDE |
| Lochinvar | Lochinvar Knight FTXL (ProtoNode FPC-N54)Lochinvar Knight FTXL fire-tube boilers, read through the ProtoNode FPC-N54 gateway. · Document Revision 5.A (Lochinvar 2000594856 Rev A) Also known as: Knight FTXL, FTXL, Lochinvar FTXL, ProtoNode FPC-N54 | Boiler | 46 | 12 | CSVEDE |
| Lochinvar | Lochinvar Lectrus electric boiler (KEB)Lochinvar Lectrus electric boilers, models KEB 0015-0150, with the Modbus/BACnet communication board. · 100389961_2000844370 Also known as: Lectrus, KEB, KEB0015, KEB0150, MODB-I-O-KEB, Lochinvar electric boiler | Boiler | 39 | 10 | CSVEDE |
| Lochinvar | Lochinvar Power Fin 2.5-5.0 (ProtoNode FPC-N54)Lochinvar Power Fin boilers in the 2.5-5.0 size range (the guide's "Powerfin_2.5_5.0" profile), read through the ProtoNode FPC-N54 gateway. · Document Revision 5.A (Lochinvar 2000594856 Rev A) Also known as: Power Fin 2.5-5.0, Power-Fin 2500-5000, PBN/PFN 2.5-5.0, Lochinvar Power Fin, ProtoNode FPC-N54 | Boiler | 55 | 10 | CSVEDE |
| Lochinvar | Lochinvar Power-Fin (SMART SYSTEM)Lochinvar Power-fin models 502-1302 and 1501-2001, with the SMART SYSTEM control and the Modbus/BACnet communication board. · PBX-PFX-MODB_100161633_2000016132 Also known as: Power-fin, Powerfin, PBX-PFX-MODB, SMART SYSTEM | BoilerWater heater | 51 | 10 | CSVEDE |
| Lochinvar | Lochinvar RegentRegent IWH 500-1000 commercial gas water heaters. · 100161012_2000020084 Also known as: Regent IWH, IWH500-1000 | Water heater | 63 | 7 | CSVEDE |
| Lochinvar | Lochinvar SYNCSYNC 1.0, 1.3 and 1.5 condensing boilers (two heat exchangers, reported as unit 1 and unit 2). · SYNC-MODB_100161723_2000017706 Also known as: SYNC 1.0, SYNC 1.3, SYNC 1.5, SYNC-MODB | BoilerCondensing | 62 | 9 | CSVEDE |
| Navien | Navien NFB-C Fire Tube Boiler - Cascade Main + Sub 1-31 (Modbus/BACnet Gateway)A cascade of Navien NFB-C boilers (one Main and up to 31 Subs) connected to the Navien Modbus/BACnet gateway through the Main boiler. Also known as: NFB-C cascade, NFB-301C, NFB-399C, Navien Modbus/BACnet Gateway, GXXX001932 | Boiler | 580 | 21 | CSVEDE |
| Navien | Navien NFB-C Fire Tube Boiler - Single Boiler (Modbus/BACnet Gateway)A single Navien NFB-C boiler (NFB-301C/399C) connected to the Navien Modbus/BACnet gateway. Also known as: NFB-C, NFB-301C, NFB-399C, Navien Modbus/BACnet Gateway, GXXX001932 | Boiler | 66 | 21 | CSVEDE |
| Patterson-Kelley | Patterson-Kelley ENVI boiler control (ProtoNode FPC-N34/N35)Patterson-Kelley boilers with the ENVI control, read through the ProtoNode FPC-N34 / FPC-N35. · Document Revision 14.B Also known as: ENVI, P-K ENVI, Patterson-Kelley ENVI, ProtoNode FPC-N34 | Boiler | 53 | 9 | CSVEDE |
| Patterson-Kelley | Patterson-Kelley LOVE controller (ProtoNode FPC-N34/N35)Patterson-Kelley equipment with a LOVE temperature controller, read through the ProtoNode FPC-N34 / FPC-N35. · Document Revision 14.B Also known as: LOVE, P-K LOVE, Patterson-Kelley LOVE, ProtoNode FPC-N34 | Boiler | 40 | 25 | CSVEDE |
| Patterson-Kelley | Patterson-Kelley NURO boiler control (ProtoNode FPC-N34/N35)Patterson-Kelley boilers with the NURO control (SOLA based), read through the ProtoNode FPC-N34 / FPC-N35. · Document Revision 14.B Also known as: NURO, P-K NURO, Patterson-Kelley NURO, ProtoNode FPC-N34 | Boiler | 64 | 12 | CSVEDE |
| Peerless | Peerless PureFire PF-460, PF-850, PF-1000, PF-1500 (852IF) - ProtoNodePeerless PureFire PF-460, PF-850, PF-1000 and PF-1500 boilers (852IF interface), read through a ProtoNode FPC-N34 gateway. · PF8296 R0 Also known as: PureFire, 852IF, PF-460, PF-850, PF-1000, PF-1500, ProtoNode FPC-N34, PB Heat | Boiler | 35 | 6 | CSVEDE |
| Peerless | Peerless PureFire PF-50 to PF-399 (PFA-1) - ProtoNodePeerless PureFire PF-50 through PF-399 boilers (PFA-1 control), read through a ProtoNode FPC-N34 gateway. · PF8296 R0 Also known as: PureFire, PFA-1, PF-50, PF-399, ProtoNode FPC-N34, PB Heat | Boiler | 16 | 2 | CSVEDE |
| PVI | PVI EOS (BTCII) boiler control - HeatStationPVI HeatStation boilers with the EOS BTCII touch-screen control, standalone or as the master of a cascade of up to 12 boilers, firmware J1239D-570 or newer. · PV7214 (PN 144593) Also known as: PVI EOS boiler, BTCII, EOS Controller, HeatStation, PVI HeatStation, J1239D-570, PV7214 | Boiler | 37 | 7 | CSVEDE |
| PVI | PVI EOS (BTCII) water heater controlPVI water heaters with the EOS BTCII touch-screen control (Conquest 100 and 130 gallon, Power VTX, TurboPower 96), firmware J1239D-570 or newer. · PV7213 (PN 144594) Also known as: PVI EOS, BTCII, EOS Controller, Conquest, PVI Conquest, J1239D-570, PV7213, Power VTX, TurboPower 96 | Water heater | 37 | 7 | CSVEDE |
| Raypak | Raypak VERSA IC - ProtoNode RER/LER (B-85 / B-86)Raypak boilers and water heaters with the VERSA IC control platform, connected through the ProtoNode RER (B-85) or LER (B-86) gateway. · P/N 241515 Rev. 5 Also known as: VERSA IC, Versa IC, ProtoNode RER, ProtoNode LER, FPC-N34, FPC-N35, B-85, B-86, 241515 | Boiler | 173 | 32 | CSVEDE |
| RBI | RBI FIII / Fusion / CK boilers with HeatNet V3 controlRBI (Mestek) Futera III, Fusion and CK Series boilers with a HeatNet V3 control board, including HeatNet cascades of up to 16 boilers. · V1.00 Also known as: HeatNet V3, HeatNet, Futera III, FIII, Futera Fusion, Fusion, CK Series, Mestek, RBI V3 BACnet Objects | Boiler | 99 | 20 | CSVEDE |
| Regin | Regin Exigo 4.3 heating controllerRegin Exigo 4.3 heating controllers: up to 4 heating circuits, 2 hot-water circuits, boilers, district heating, solar and buffer tanks. · BACnet_Exigo43_EDE Also known as: Exigo 4.3, Exigo, Exigo Ardo, Exigo Vido, Regin Exigo, BACnet_Exigo43 | Boiler | 623 | 236 | CSVEDE |
| Smith Cast Iron Boilers | Smith Cast Iron Boilers S28 Series boiler - HeatNet BACnet BridgeSmith Cast Iron Boilers (Mestek) S28 Series boilers with a HeatNet control and the HeatNet BACnet bridge. · v2.52 Also known as: S28, Smith S28, S28 Series, HeatNet, HeatNet bridge, Mestek | Boiler | 86 | 18 | CSVEDE |
| Thermal Solutions | Thermal Solutions ALTA / Phantom II boiler control (Universal Gateway ProtoAir)U.S. Boiler ALTA and ALTAC and Velocity Boiler Works Phantom II and Phantom Combi II boilers, connected to the Universal Gateway (ProtoAir FPA-W44) on the control's Modbus 2 port. · PN 106417-04 Rev A Also known as: ALTA, ALTAC, U.S. Boiler ALTA, Phantom II, Phantom Combi II, Velocity Boiler Works Phantom II, ProtoAir FPA-W44, Universal Gateway 106417-04 | Boiler | 35 | 4 | CSVEDE |
| Thermal Solutions | Thermal Solutions Apex / Arctic with Concert or Panasonic 4716 software (Universal Gateway)Thermal Solutions Apex and Arctic boilers with the Concert control and display, and Apex boilers with the Panasonic display running 4716 software, through the Universal Gateway. · 106417-01 Rev. 13 Also known as: Concert, Concert control, Apex 4716, Arctic, Arctic 1000, Arctic 1500, Universal Gateway, 106417-01, ProtoNode RER, FPC-N34-0816 | Boiler | 45 | 12 | CSVEDE |
| Thermal Solutions | Thermal Solutions Apex with Panasonic display, 4109 software (Universal Gateway)Thermal Solutions Apex boilers with the control and Panasonic GT02 display running 4109 software, connected through the Universal Gateway. · 106417-01 Rev. 13 Also known as: Apex, Apex 4109, Panasonic GT02, Universal Gateway, 106417-01, ProtoNode RER, FPC-N34-0816 | Boiler | 28 | 10 | CSVEDE |
| Thermal Solutions | Thermal Solutions Conductor EMS boiler sequencer (ProtoAir FPA-W44)Thermal Solutions / Bryan Steam Conductor EMS boiler sequencers (up to 8 boilers) connected to BACnet through the ProtoAir FPA-W44 gateway. · 106417-02 Rev 13 Also known as: Conductor, Conductor EMS, Bryan Steam Conductor, ProtoAir FPA-W44, 106417-02, Thermal Solutions master sequencer | Boiler | 222 | 2 | CSVEDE |
| Thermal Solutions | Thermal Solutions EVA / EVO boiler - RM7800 flame safeguard (ProtoNode)Thermal Solutions EVA, EVAW, EVO and EVOW boilers with an RM7800 series burner control, connected through a ProtoNode FPC-N34. · Document Revision 7.A (Web Configurator Template Revision 70) Also known as: RM7800, Honeywell RM7800, 7800 Series, EVA, EVAW, EVO, EVOW, FPC-N34-0643, ProtoNode FPC-N34 | Boiler | 37 | 0 | CSVEDE |
| Thermal Solutions | Thermal Solutions EVA / EVO boiler - RWF40 controller (ProtoNode)Thermal Solutions EVA, EVAW, EVO and EVOW boilers whose operating control is an RWF40, connected through a ProtoNode FPC-N34. · Document Revision 7.A (Web Configurator Template Revision 70) Also known as: RWF40, Siemens RWF40, EVA, EVAW, EVO, EVOW, FPC-N34-0643, ProtoNode FPC-N34 | Boiler | 15 | 8 | CSVEDE |
| Thermal Solutions | Thermal Solutions EVA / EVO boiler - RWF55 controller (ProtoNode)Thermal Solutions EVA, EVAW, EVO and EVOW boilers whose operating control is an RWF55, connected through a ProtoNode FPC-N34. · Document Revision 7.A (Web Configurator Template Revision 70) Also known as: RWF55, Siemens RWF55, EVA, EVAW, EVO, EVOW, FPC-N34-0643, ProtoNode FPC-N34 | Boiler | 10 | 2 | CSVEDE |
| Thermal Solutions | Thermal Solutions Fireye YB110 flame safeguard (Universal Gateway ProtoAir)Thermal Solutions and Bryan boilers with a Fireye YB110 flame safeguard, connected to the Universal Gateway (ProtoAir FPA-W44). · PN 106417-04 Rev A Also known as: YB110, Fireye YB110, BurnerPRO, Fireye, ProtoAir FPA-W44, Universal Gateway 106417-04 | Boiler | 97 | 0 | CSVEDE |
| Thermal Solutions | Thermal Solutions Precision Digital Trident PD765 meter (Universal Gateway ProtoAir)A Precision Digital Trident PD765 process meter used in Thermal Solutions and Bryan boiler control systems, connected to the Universal Gateway (ProtoAir FPA-W44). · PN 106417-04 Rev A Also known as: PD765, Trident PD765, Precision Digital PD765, ProtoAir FPA-W44, Universal Gateway 106417-04 | Boiler | 32 | 28 | CSVEDE |
| Thermal Solutions | Thermal Solutions Siemens LMV2 / LMV3 burner management (Universal Gateway ProtoAir)Thermal Solutions and Bryan boilers fired by a Siemens LMV2x or LMV3x burner management system, connected to the Universal Gateway (ProtoAir FPA-W44). · PN 106417-04 Rev A Also known as: LMV2_3, LMV2, LMV3, LMV26, LMV37, Siemens LMV2x/3x, ProtoAir FPA-W44, Universal Gateway 106417-04 | Boiler | 81 | 13 | CSVEDE |
| Thermal Solutions | Thermal Solutions Siemens LMV36 burner management (Universal Gateway ProtoAir)Thermal Solutions and Bryan boilers fired by a Siemens LMV36 burner management system, connected to the Universal Gateway (ProtoAir FPA-W44). · PN 106417-04 Rev A Also known as: LMV36, Siemens LMV36, LMV3, ProtoAir FPA-W44, Universal Gateway 106417-04 | Boiler | 9 | 3 | CSVEDE |
| Thermal Solutions | Thermal Solutions Siemens LMV52 burner management (Universal Gateway ProtoAir)Thermal Solutions and Bryan boilers fired by a Siemens LMV52 burner management system, connected to the Universal Gateway (ProtoAir FPA-W44). · PN 106417-04 Rev A Also known as: LMV52, Siemens LMV52, LMV5, ProtoAir FPA-W44, Universal Gateway 106417-04, Bryan Boiler LMV52 | Boiler | 32 | 5 | CSVEDE |
| Thermal Solutions | Thermal Solutions Siemens RWF55 boiler controller (Universal Gateway ProtoAir)Thermal Solutions and Bryan boilers that use a Siemens RWF55 temperature/pressure controller, connected to the Universal Gateway (ProtoAir FPA-W44). · PN 106417-04 Rev A Also known as: RWF55, Siemens RWF55, ProtoAir FPA-W44, Universal Gateway 106417-04, Bryan Boiler RWF55 | Boiler | 25 | 17 | CSVEDE |
| Thermal Solutions | Thermal Solutions TSBC boiler control (Universal Gateway)Thermal Solutions boilers with the TSBC control (such as EVS and EVCA), connected through the Thermal Solutions Universal Gateway. · 106417-01 Rev. 13 Also known as: TSBC, Thermal Solutions Boiler Control, Universal Gateway, 106417-01, ProtoNode RER, FPC-N34-0816, EVS, EVCA | Boiler | 58 | 2 | CSVEDE |
| Viessmann | Viessmann Vitocrossal 200 CI2 (WAGO Automation Gateway)Viessmann Vitocrossal 200 CI2 boilers connected to a WAGO Automation Gateway BACnet IP, as a single boiler or in a cascade. · 6178 508-05 Also known as: Vitocrossal 200, Vitocrossal CI2, Viessmann WAGO gateway, WAGO Automation Gateway BACnet/IP, 6178 508 | Boiler | 129 | 15 | CSVEDE |
| Viessmann | Viessmann Vitodens 200-W B2HE (WAGO Automation Gateway)Viessmann Vitodens 200-W B2HE wall-mounted boilers connected to a WAGO Automation Gateway BACnet IP, as a single boiler or in a cascade. · 6178 507-04 Also known as: Vitodens 200, Vitodens 200-W, Vitodens B2HE, Viessmann WAGO gateway, WAGO Automation Gateway BACnet/IP, 6178 507 | Boiler | 120 | 15 | CSVEDE |
| Watts | Watts tekmar Boiler Control 284tekmar Boiler Control 284, which stages and modulates up to four boilers for heating and DHW loads. · 284_B Also known as: tekmar 284, Boiler Control 284, 284, tekmar multi-staging 284 | Boiler | 72 | 13 | CSVEDE |
| Watts | Watts tekmar Smart Boiler Control 294BACtekmar (Watts) Smart Boiler Control 294BAC, a staging and reset control for plants of up to 16 boilers with DHW, connected natively over BACnet IP or BACnet MS/TP. · IS-T-294BAC 2627 Also known as: tekmar 294BAC, 294BAC, tekmar 294, Smart Boiler Control 294, J1308 | Boiler | 241 | 107 | CSVEDE |
| Watts | Watts tekmar Snow Melting Control 680tekmar (Watts) Snow Melting Control 680 for hydronic or electric snow melting slabs, with boiler and mixing outputs. · 680_B Also known as: tekmar 680, Snow Melting Control 680, 680, tekmar snow melt 680, J1243F | Boiler | 52 | 18 | CSVEDE |
| Weil-McLain | Weil-McLain Evergreen / SlimFit Series 2 & 3 / SVF - ProtoNodeWeil-McLain Evergreen, SlimFit 550-750 Series 2 & 3, SlimFit 1000-2000 Series 2 and SVF boilers, read through a ProtoNode FPC-N34 gateway. · T17022 Also known as: Evergreen, SlimFit 550-750, SlimFit 1000-2000 Series 2, SVF, ProtoNode FPC-N34, ProtoNode FPC-N35, ProtoNode | Boiler | 831 | 111 | CSVEDE |
| Weil-McLain | Weil-McLain SlimFit 1000-2000 - UPC BACnet translatorWeil-McLain SlimFit 1000-2000 boilers (SOLA control) fitted with the UPC BACnet translator kit 383-600-304. · 550-100-130/1113 Also known as: SlimFit, SlimFit 1000, SlimFit 2000, UPC BACnet, 383-600-304, SOLA | Boiler | 144 | 36 | CSVEDE |
| Weil-McLain | Weil-McLain SlimFit 1000-2000 Series 1 (SOLA) - ProtoNodeWeil-McLain SlimFit 1000-2000 Series 1 boilers with the Honeywell SOLA control, read through a ProtoNode FPC-N34 gateway. · T17022 Also known as: SlimFit Series 1, SlimFit SOLA, SOLA, ProtoNode FPC-N34, ProtoNode FPC-N35, ProtoNode | Boiler | 144 | 21 | CSVEDE |